MILKING PROCEDURE
  • Start the vacuum pump and adjust the vacuum level at 50  kpa while vacuum cock (4) is closed.

  • Attach tube (12) from vacuum cock to adopter on bucket lid (8) and open cock.

  • Clean the animal teats (A above) and hand strip the initial milk (B above)

  • Holding claw in one hand, make sure the teat a cup and shell drops (Bend) over the claw nipples.

  • Open the Claw valve on bottom of claw.

  • Try to complete above steps in quick manner so that milking vacuum is not lost.

  • When animal is finishing milking, cab be seen through the transparent part of cluster (9) close the claw valve (13)

  • The empty the bucket, first close the vacuum cock, then open the claw valve to release bucket vacuum

Washing Procedure

  • Use the wash unit (6) for automatically cleaning (upto 4 Cluster unit) of milk tube claw and liner simultaneously.

 

  1  |  2